SECO-LARM SS-072Q Specifications

Browse online or download Specifications for Security device components SECO-LARM SS-072Q. SECO-LARM SS-072Q User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
SS-072Q
Tamper Switch
UL Listed for Supplementary Protection
FEATURES:
!
Used in alarm systems with normally-closed circuits.
!
Silver-plated contact ensures reliability and long-term operation.
!
Small size makes it easy to hide and install.
SPECIFICATIONS:
!
Plunger Pushed in: Contact closed
!
Plunger Released: Contact Open
!
Contact Rating: 0.5A at 50 VDC
!
Enclosure: High-impact Plastic Resin
! Size: 2-
3
/
4
” x 1-
1
/
16
” x
5
/
8
” (70 x 28 x 16mm)
! Weight: 18 gm
INSTALLATION INSTRUCTIONS:
1. Decide the appropriate position for the SS-072Q. (Note that the switch must be positioned so that it will be depressed at least
1/4” [6mm] to activated).
2. Drill the three holes necessary for the SS-072Q to be mounted firmly in place. The diameter of the hole is 1/8” (3mm). Screws
should be selected according to your own particular preference and need.
3. Connect the wires to the switch terminals, using series circuitry, see illustration on Fig.1.
Minimum activation distance
Drill three holes, each
hole 1/8” (3mm) and insert screws.
Connect the wires to switch terminals using series circuitry.
To alarm system
Inside of
alarm case
1/4”(6mm)
Fig.1- Used inside cabinet or drawer when
cabinet or drawer is pulled open.
Important Note: When mounting the tamper switch, keep in
mind that the switch must be depressed at least 1/4” (6mm)
distance in order to activate the switch.
Note: Products with model number that ends with "Q" or have a green “Q” sticker represents RoHS compliant products.
ENFORCER
®
Type: S
49J5
Page view 0
1 2

Summary of Contents

Page 1 - ENFORCER

SS-072QTamper SwitchUL Listed for Supplementary ProtectionFEATURES:!Used in alarm systems with normally-closed circuits.!Silver-plated contact ensures

Page 2 - The SECO-LARM

Case bodyFig.2- Case against wall.Use 2 SS-072Q to protect against the forcedremoval of the case from the wall and the forcedremoval of the case’s cov

Comments to this Manuals

No comments